Integrated DOL Control Motor Starter Box With Phase Loss Protection Inner Circuit

Specifications
Features: Overload Protection, Short Circuit Protection, Thermal Relay Currentrating: 10A-100A
Operatingtemperature: -20°C To 60°C Material: Metal/Plastic
Controltype: Manual/Automatic Application: Motor Control And Protection
Mountingtype: Wall-mounted/Panel-mounted Color: Gray/Blue
Highlight

Integrated Motor Starter Box

,

DOL Control Motor Starter Box

,

Three Phase Motor Starter Box

Product Description
Integrated DOL Control Motor Starter Box with Phase Loss Protection Inner Circuit
Product Overview

Safeguard your industrial electromotors and optimize control systems with our Integrated DOL (Direct-On-Line) Control Motor Starter Box. Specifically engineered for low-voltage, high-torque three-phase induction motors, this enclosed magnetic starter combines convenient push-button operation with an advanced interior protection circuit.

Featuring an integrated phase loss protection circuit, this control box continuously monitors power supply consistency. If a single phase drops out due to blown fuses, line breaks, or grid faults, the starter cuts power within milliseconds—preventing catastrophic motor winding burnouts, maximizing machine uptime, and ensuring strict compliance with industrial electrical safety standards.

Technical Specifications
Parameter Specifications & Compliance Standards
Starter Type Integrated Direct-On-Line (DOL) Magnetic Motor Starter
Main Protection Circuit Dynamic Phase Loss Protection & Thermal Overload Relay
Rated Operational Voltage 380V / 400V / 415V AC (Three-Phase, 50/60Hz)
Supported Motor Power 0.75 kW to 37 kW (Choose tailored contactor/overload modules)
Control Coil Voltage 24V, 110V, 220V, or 380V AC (Customizable options)
Enclosure Material High-Impact ABS Plastic / Heavy-Duty Cold-Rolled Steel Sheet
Ingress Protection (IP) IP65 (Dust-tight and protected against rain/water jets)
Interface Controls Green (START / Run) & Red (STOP / RESET) Push Buttons
Certifications CE, RoHS, IEC/EN 60947-4-1 Compliant
Integrated DOL Control Motor Starter Box with phase loss protection circuit
Core Engineering & Electrical Advantages
Active Phase Loss Detection Inner Circuit

The true core of this control box is its highly responsive internal monitoring circuit. "Single-phasing" is a leading cause of motor insulation degradation and critical damage. Our integrated protection relay instantly identifies unbalanced current distribution or an absent voltage phase, dropping out the contactor coil prior to motor overheating to eliminate costly repair downtime.

Comprehensive Thermal Overload Integration

Beyond phase monitoring, the starter features an adjustable ambient-compensated thermal overload relay. This allows field electricians to dial in the exact Full Load Amps (FLA) of the connected motor, protecting the machinery against sustained overcurrent, heavy mechanical binding, and prolonged locked-rotor conditions.

Dustproof & Waterproof IP65 Rugged Housing

Designed for both aggressive factory floors and harsh outdoor utility installations, the enclosure features an all-weather polyurethane sealing gasket. The robust shell resists chemical corrosion, UV degradation, and physical impacts, ensuring continuous localized automation and protection in demanding work zones.

Pre-Wired Internal Layout for Rapid Setup

Skip complex field wiring. The internal contactor, control circuit transformers, protection relays, and indicator pathways are fully integrated and factory pre-wired. Installers only need to connect the main 3-phase incoming power lines to the input terminals and route the output lines directly to the motor terminals.

Industrial Application Scenarios
  • Pumping & Irrigation Infrastructure: Manages high-horsepower agricultural water pumps and wastewater submersible units against phase failure from rural grid drops.
  • HVAC Fan & Air Compressor Systems: Delivers reliable, enclosed local control for commercial exhaust fans, cooling tower blowers, and industrial air compressors.
  • Conveyors & Material Handling: Ideal for gravel sorters, grain elevators, and factory assembly lines where mechanical jams cause abrupt motor overloading.
  • Industrial Automation Systems: Acts as a rugged standalone sub-panel controller for mixers, lathes, and processing machinery across production facilities.
Why Partner With Us?
  • 100% Parameter Validation: Each DOL starter box undergoes automated functional testing, dialectic withstand verification, and simulation phase-loss triggers before export dispatch.
  • Flexible OEM/ODM Engineering: We provide customized options including internal terminal extensions, custom brand labeling, added external voltmeters/ammeters, or auxiliary contact blocks.
  • Seaworthy Export Logistics: All items are wrapped in anti-static moisture-barrier film and shipped in structural, impact-resistant export cartons to guarantee pristine on-site arrival.
Frequently Asked Questions
How fast does the inner circuit respond during a phase failure?
The phase loss protection relay operates on an inverse time-delay mechanism or immediate drop-out path, usually tripping the control circuit within 1 to 3 seconds to ensure the motor windings do not experience damaging thermal accumulation.
Can this box be used with single-phase 220V motors?
No, this integrated starter box is specifically wired and engineered with a 3-phase inner detection circuit to manage 380V-415V three-phase motors. For single-phase applications, please contact our support desk for our single-phase DOL model variants.
Is it easy to adjust the overload current settings?
Yes. Simply open the enclosure cover to access the dial on the thermal overload relay. Using a standard flat-head screwdriver, you can easily adjust the current pointer to match your motor's nameplate FLA rating.
Contact Details
Xiamen Rongmai Electrical Equipment Co., Ltd.

Contact Person: Mr. Tan

Tel: 86--8615960356367

Send your inquiry directly to us